What was found
TUL - FOUND CORROSION ON FLOORBEAM AT FRAME 61 AND NR 5 ROLLER TRAY. SPLICED FRAME SECTION PER SRM 53-10-15-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON FLOORBEAM AT FRAME 61 AND NR 5 ROLLER TRAY. SPLICED FRAME SECTION PER SRM 53-10-15-2. (M)