What was found
DFW - DURING OVERNIGHT MAINTENANCE, AFT CABIN EMERGENCY LIGHTS INOPERATIVE. FOUND LOOSE CONNECTOR AT AFT GALLEY DOOR FLOOR EXIT SIGN. REPAIRED CONNECTOR AT AFT GALLEY DOOR FLOOR EXIT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DFW - DURING OVERNIGHT MAINTENANCE, AFT CABIN EMERGENCY LIGHTS INOPERATIVE. FOUND LOOSE CONNECTOR AT AFT GALLEY DOOR FLOOR EXIT SIGN. REPAIRED CONNECTOR AT AFT GALLEY DOOR FLOOR EXIT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)