What was found
TUL - FLOORBOARD SUPPORT HAS CORROSION AT 1887-1897 APPROXIMATELY 40 INCHES RIGHT OF CENTERLINE. INSTALLED FABRICATED REPAIR PER SRM 53-60-01 AND DOUBLER PER SRM 53-60-01. TST: 96,680.24 HOURS. CYCLES: 18,100. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FLOORBOARD SUPPORT HAS CORROSION AT 1887-1897 APPROXIMATELY 40 INCHES RIGHT OF CENTERLINE. INSTALLED FABRICATED REPAIR PER SRM 53-60-01 AND DOUBLER PER SRM 53-60-01. TST: 96,680.24 HOURS. CYCLES: 18,100. (X)