What was found
TUL - FOUND FIGURE 8 HOLE AT FUSELAGE TORQUE TUBE UPPER CASTING AT FASTENER HOLE. APPLIED SEALANT PER SRM 51-20-4 TO FIXING SURFACE ON NEW CASTING NR 65-57535-9 AND INSTALLED PER SRM 51-10-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FIGURE 8 HOLE AT FUSELAGE TORQUE TUBE UPPER CASTING AT FASTENER HOLE. APPLIED SEALANT PER SRM 51-20-4 TO FIXING SURFACE ON NEW CASTING NR 65-57535-9 AND INSTALLED PER SRM 51-10-1. (M)