What was found
TUL - FOUND STRINGER CLIP CORRODED. ALODINED, PRIMED AND PAINTED AREA PER SRM 51-75-10-2. INSTALLED NEW STRINGER END PER SRM 51-72-10-10 W/SPLICE PER SRM 53-10-14-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER CLIP CORRODED. ALODINED, PRIMED AND PAINTED AREA PER SRM 51-75-10-2. INSTALLED NEW STRINGER END PER SRM 51-72-10-10 W/SPLICE PER SRM 53-10-14-2. (M)