What was found
TUL - STRINGER 54L AT FRAME 59 TO 60 HAS CORROSION. REPLACED DAMAGED SECTION OF STRINGER ADDED NEW SPLICE ON AFT END OF NEW SECTION. REINSTALLED FORWARD SPLICE AS PER SRM 51-72-10-0. TREATED, PRIMED AND PAINTED PER SRM 51-21-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STRINGER 54L AT FRAME 59 TO 60 HAS CORROSION. REPLACED DAMAGED SECTION OF STRINGER ADDED NEW SPLICE ON AFT END OF NEW SECTION. REINSTALLED FORWARD SPLICE AS PER SRM 51-72-10-0. TREATED, PRIMED AND PAINTED PER SRM 51-21-10. (M)