As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FRAME AT STATION 520 DENTED ABOVE STRINGER 23R. INSTALLED FRAME REPAIR PER SRM 51-40-3. REMOVED DAMAGE AREA, INSTALLED 13 INCH DOUBLER OF .073 7075-T6 WITH THIRTY FOUR .375 D-RIVETS AND FOUR .25 INCH D-RIVETS, TWO .375 INCH SCREWS AND SIX .375 INCH BOLTS. (M)