What was found
TUL - FOUND CRACK COMING FROM FASTENER 12 INCHES FORWARD OF STATION 1110 AT NR 2 ENGINE INTAKE DOG HOUSE STRINGER NR 1. CUT OUT DAMAGE SKIN PER SRM 53-30-3 PAGE 12 AND INSTALLED DOUBLER PER BOEING S/B 727-53AD204. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CRACK COMING FROM FASTENER 12 INCHES FORWARD OF STATION 1110 AT NR 2 ENGINE INTAKE DOG HOUSE STRINGER NR 1. CUT OUT DAMAGE SKIN PER SRM 53-30-3 PAGE 12 AND INSTALLED DOUBLER PER BOEING S/B 727-53AD204. (M)