What was found
TUL - STATION 660 BELL FRAME DENTED BETWEEN STRINGER 24L-25L. REPAIRED FRAME AS PER SRM 53-10-4 USING .063 DOUBLER AND 4 ROWS OF .1875 FASTENERS EACH SIDE OF DAMAGE OUTSIDE FRAME REPAIR. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STATION 660 BELL FRAME DENTED BETWEEN STRINGER 24L-25L. REPAIRED FRAME AS PER SRM 53-10-4 USING .063 DOUBLER AND 4 ROWS OF .1875 FASTENERS EACH SIDE OF DAMAGE OUTSIDE FRAME REPAIR. (M)