What was found
TUL - FOUND STRINGER 2L CORRODED STATION 720 D-E. REPAIRED PER SRM 53-10-3 PAGE 40. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER 2L CORRODED STATION 720 D-E. REPAIRED PER SRM 53-10-3 PAGE 40. (M)