What was found
TUL - STRINGER 15L CRACKED AT END JUST FORWARD OF ICE LIGHT HOUSING BETWEEN BS 720B AND 720A. REPAIRED STRINGER 15L BETWEEN BS 720B AND 720A PER SRM 51-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STRINGER 15L CRACKED AT END JUST FORWARD OF ICE LIGHT HOUSING BETWEEN BS 720B AND 720A. REPAIRED STRINGER 15L BETWEEN BS 720B AND 720A PER SRM 51-10-3. (M)