TUL - BELL FRAME DENTED STATION 500 IN BETWEEN STRINGER 23 LEFT AND 22 LT. CUT OUT DAMAGED AREA AND INSTALLED .071 7075-T6 DOUBLER IAW SRM 51-40-3 PER AARD 53-10-07-3. (M)