What was found
TUL - FOUND STATION 1012 STRINGER 29R HAS SKIN BULGING AROUND FASTENERS. INSTALLED NEW STRINGER SECTION AND SPLICE AS PER SRM 53-10-3 FIG 1, STRINGER SECTION BAC 1498-147. INSTALLED STATION 1011-1021. TEN INCHES OF BAC1498-131 REPAIR MATERIAL INSTALLED WITH FIVE FASTENERS EACH SIDE OF DAMAGE. .1875 1ST OVER HI-LOCKS USED THROUGHOUT REPAIR. (M)