What was found
TUL - FOUND CORROSION IN BOTTOM OF STRINGER AT NUT PLATE STATION 702. CUT OUT DAMAGED AREA OF STRINGER. INSTALLED REPAIR SPLICE AND FILLER IAW SRM 53-10-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION IN BOTTOM OF STRINGER AT NUT PLATE STATION 702. CUT OUT DAMAGED AREA OF STRINGER. INSTALLED REPAIR SPLICE AND FILLER IAW SRM 53-10-3 FIG 1. (M)