What was found
TUL - FLOORBEAM CORRODED ON UPPER FLANGE RBL 24 TO RBL 63 AT STATION 480. REPAIRED PER SRM 53-10-8, WITH APPROX 6 INCHES FILLER ON TOP FLANGE WITH ANGLES ON BOTH SIDES OF BEAM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.