What was found
TUL - FOUND BELL FRAME SPLICE DENTED STATION 600 BETWEEN STRINGER 26 LEFT - 25 RT. INSTALLED 8 INCH DOUBLER 7075 T-6 .063 WITH 20 .1875 MS20470DD RIVETS, 2 ROWS PAST DAMAGE, 1 ROW ON TOP, .75 SPACING PER 51-40-3 FIG 1 PAGE 3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND BELL FRAME SPLICE DENTED STATION 600 BETWEEN STRINGER 26 LEFT - 25 RT. INSTALLED 8 INCH DOUBLER 7075 T-6 .063 WITH 20 .1875 MS20470DD RIVETS, 2 ROWS PAST DAMAGE, 1 ROW ON TOP, .75 SPACING PER 51-40-3 FIG 1 PAGE 3. (M)