What was found
TUL - BELL FRAME STATION 620 ABOVE STRINGER 24L DENTED. INSTALLED A DOUBLER ON BELL FRAME PER SRM 51-40-3 PAGE 3-5, USING 8 INCH DOUBLER OF 7075T-6 .063 USING TWENTY .1875 INCH MS 20470D6 AND TWO .25 INCH MS20470D8 RIVETS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - BELL FRAME STATION 620 ABOVE STRINGER 24L DENTED. INSTALLED A DOUBLER ON BELL FRAME PER SRM 51-40-3 PAGE 3-5, USING 8 INCH DOUBLER OF 7075T-6 .063 USING TWENTY .1875 INCH MS 20470D6 AND TWO .25 INCH MS20470D8 RIVETS. (M)