As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FOUND BELLFRAME DENTED TOP FLANGE STATION 660 FROM STRINGER 28L TO STRINGER 24L. REMOVED DAMAGE AREA, FROM 23L-24L, STATION 660. INSTALLED .063 DOUBLER 18 INCH LONG, 7075T6 COVERED TWO DAMAGE AREAS 1 INCH BY 1.5 INCH AND 1 INCH BY 2 INCH. USED 45 EACH MS20470D RIVETS AND 4 EACH MS 20470 D8 RIVETS. (M)