What was found
TUL - FOUND BELLFRAME DENTED TOP FLANGE STATION 680 BETWEEN STRINGER 22L TO STRINGER 25L. INSTALLED REPAIR PER SRM 51-40-3 USING 7075-T6 .063 INCH THICK, 6.5 INCH BY 4 INCH USING SIXTEEN .1875 UNIVERSAL D RIVETS AND FIVE .25 INCH UNIVERSAL D RIVETS AND THREE FASTENERS ROWS. (M)