What was found
AFW - STRINGER AND STRINGER SPLICE AT 537L HAD CORROSION. FABRICATED AND REPLACEMENT STRINGER SPLICE FROM .071 INCH THICK 7075-T6 ALCLAD. INSTALLED PER SRM 51-40-02 AND 51-40-03. APPLIED ALODINE AND TWO COATS PRIMER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - STRINGER AND STRINGER SPLICE AT 537L HAD CORROSION. FABRICATED AND REPLACEMENT STRINGER SPLICE FROM .071 INCH THICK 7075-T6 ALCLAD. INSTALLED PER SRM 51-40-02 AND 51-40-03. APPLIED ALODINE AND TWO COATS PRIMER. (M)