As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FOUND AND BLENDED FIVE SMALL AREAS OF CORROSION ON THE UPPERS SURFACE OF THE LONGITUDINAL FLOORBEAM. THE BLENDOUTS EXCEED SRM MAX ALLOWABLE LIMITS. ROTOPEENED, TREATED, PRIMED AND FILLED BLEND AREAS. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1634. (M)