As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FOUND AND BLENDED OUT CORROSION ON THE UPPER SURFACE OF THE UPPER CAP OF FLOORBEAM. THE BLENDOUT EXCEEDED SRM MAX ALLOWABLE LIMITS. ALODINED BLENDOUT. FABRICATED AND INSTALLED REPAIR STRAP USING .050 301.5 HARD STAINLESS STEEL. FILLED AND PRIMED AS REQUIRED. APPROVED BY ENGINEERING PER MRB 767-1647. (M)