What was found
AFW - FRAME AT STA 412 HAS CORROSION REMOVAL ON UPPER AND LOWER SURFACE. BLENDED AND REFINISHED AREA PER SRM 53-00-07 FIG 101. THE FRAME IS ACCEPTABLE TO RETURN TO SERVICE. TST: 50,291.20 HOURS. CYCLES: 15,033. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FRAME AT STA 412 HAS CORROSION REMOVAL ON UPPER AND LOWER SURFACE. BLENDED AND REFINISHED AREA PER SRM 53-00-07 FIG 101. THE FRAME IS ACCEPTABLE TO RETURN TO SERVICE. TST: 50,291.20 HOURS. CYCLES: 15,033. (X)