What was found
AFW - FLOORBEAM AT STATION 938 LBL 33.06 HAD GOUGE BLENDED BEYOND SRM LIMITS. BLENDED OUT GOUGE. ROTO/FLAP PEENED BLENDED AREA. ALODINED AREA. APPLIED TWO COATS OF BMS 10-11 PRIMER AND FILLED BLENDED AREA WITH BMS 5-92 PER SRM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.