As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 904 LBL 33 HAD CORROSION BLENDED ON TOP SURFACE. BLEND OUT GOUGES, ENSURED THAT ALL DAMAGE HAS BEEN REMOVED. ROTO/FLAP PEEN BLENDED AREA PER SRM 51-20-06 ALODINE AND APPLY 2 COATS OF PRIMER FILL WITH BMS-5-95 REF MRB 767-1703. (M)