As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 1565 LBL 77 HAD CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301 1/2H STAINLESS STEEL .050 INCH THICK. ALODINE ALL BARE ALUMINUM SURFACE FINISH BLEND AND REPAIR PARTS WITH 2 COATS BMS10-11 PRIMER FILL BLENDS WITH BMS5-92. INSTALL REPAIR STRAP WET WITH BMS5-95. (M)