AFW - FLOORBEAM AT STATION 325 RBL 20 HAD CORROSION. REMOVED ALL CORROSION IAW REF C ALODINE, FINISH WITH 2 COATS OF BMS10-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FLOORBEAM AT STATION 325 RBL 20 HAD CORROSION. REMOVED ALL CORROSION IAW REF C ALODINE, FINISH WITH 2 COATS OF BMS10-11. (M)