What was found
TUL - STATION 1110 FRAME DENTED ON TOP 2 PLACES AT STRINGER 26L. REMOVED DAMAGE. INSTALLED 7075-T6 .071 DOUBLER 13 INCHES LONG PER SRM 51-40-3 FIG 1. REFERRED FROM AARD 53-10-7-3 PAGE 1, 3 ROWS AD RIVETS ON WEB, R ROW .1875 RIVETS TOP FLANGE 10 FASTENERS 21 EACH .1875 TWO ROWS, 11 EACH .25 ON ONE ROW. (M)