What was found
TUL - FOUND DENT AT BELL FRAME ABOVE STRINGER 23L. REMOVED DAMAGED AREA ABOVE STRINGER. REMOVED DAMAGED AREA ABOVE STRINGER 23L STATION 600 CUTOUT 1 INCH BY 1 INCH AREA. INSTALLED 8 INCH DOUBLER 7075-T6 .063 INSTALLED 21 RIVETS MS20470D 3 ROWS TOTAL PER SRM 51-40-3 PAGE 3 FIG 1. (M)