As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - BELL FRAME STATION 600 BETWEEN STRINGER 4R AND 5R CRACKED. REMOVED DAMAGED AREA 1..875 INCH. INSTALLED DOUBLER 15 INCHES LONG .071 7075-T6 INNER 15 INCH .080 7075-T6 OUTER, .050 2024-T3 FILLER 4 ROWS OF FASTENER 51 BACB30FA16. (M)