As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FOUND DENT AT BELL FRAME STATION 600 ABOVE STRINGER 24L DENT AT BELL FRAME STATION 600 ABOVE STRINGER 25L. REMOVED DAMAGE AREA 1 INCH AND 1 INCH ABOVE 24L 1 INCH BY 1 INCH ABOVE STRINGER 25L. INSTALLED 20 INCH DOUBLER, 7075-T6 .063 INSTALLED 53 RIVETS .1875 AND FOUR .25 3 ROWS TOTAL PER SRM 51-40-3 PAGE 3 FIG 1. (M)