What was found
TUL - STATION 1070 FRAME DENTED ON TOP BETWEEN STRINGER 26R AND 27R. INSTALLED DOUBLER WET AT STATION 1070 BETWEEN STRINGER 26R AND 27R PER SRM 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STATION 1070 FRAME DENTED ON TOP BETWEEN STRINGER 26R AND 27R. INSTALLED DOUBLER WET AT STATION 1070 BETWEEN STRINGER 26R AND 27R PER SRM 53-10-4. (M)