What was found
TUL - FRAME BENT AT FLANGE AND WEB STATION 950F STRINGER 25L TO 26L. REPAIRED FRAME PER SRM 51-40-3 WITH .071 INCH 7075-T6 MATERIAL MS2047008 FASTENERS MS20470D6 FASTENERS IN WEB AND BACB30FQ6 FASTENERS IN FLANGE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FRAME BENT AT FLANGE AND WEB STATION 950F STRINGER 25L TO 26L. REPAIRED FRAME PER SRM 51-40-3 WITH .071 INCH 7075-T6 MATERIAL MS2047008 FASTENERS MS20470D6 FASTENERS IN WEB AND BACB30FQ6 FASTENERS IN FLANGE. (M)