As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FOUND STATION 420 FRAME CRACKED AT STRINGER 10L. REPAIRED DAMAGED FRAME STATION 420 STRINGER 10L WITH DOUBLER AS PER SRM 53-10-4 PAGE 3-6 FIG 1 SHEET 4. INSTALLED DOUBLER ONE GAUGE HEAVIER THAN ORIGINAL AND USED HI-LOCK .15625 DIAMETER. (M)