TUL - FOUND TOP OF BELL FRAME DENTED AT STAITON 950F 5 INCHES ABOVE STRINGER 26L. CUTOUT DAMAGED AREA, DUE CHECKED, FABRICATED DOUBLER, AND INSTALLED PER SRM 53-10-4 PAGE 4 FIG 1. (M)