What was found
TUL - STATION 580 BELL FRAME HAS TWO DENTS AT STRINGER 23L TO STRINGER 24L. INSTALLED DOUBLER 7075T6 .063, 3 ROWS OF RIVETS 1 ROW IN TOP, 2 ROWS ON SIDE WITH THIRTY .1875 D-RIVETS AND FOUR EACH HI-LOCKS IN SHEAR TIE, STD .15625 ATTACHING TO STRINGER PER SRM 51-40-3. (M)