What was found
TUL - FOUND STATION 910 UPLOCK FRAME CRACKED ON FORWARD FLANGE. STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-10-2 PAGE 28. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STATION 910 UPLOCK FRAME CRACKED ON FORWARD FLANGE. STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-10-2 PAGE 28. (M)