What was found
TUL - FOUND STATION 1090, 3 INCH BELOW STRINGER 17 LT HAS DEEP DENT IN FUSE SKIN. INSTALLED REPAIR DOUBLER PER SRM 53-30-3, AFTER CUT OUT DAMAGED AREA. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STATION 1090, 3 INCH BELOW STRINGER 17 LT HAS DEEP DENT IN FUSE SKIN. INSTALLED REPAIR DOUBLER PER SRM 53-30-3, AFTER CUT OUT DAMAGED AREA. (M)