As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FOUND CRACK INDICATED ON WEB SURFACE EXTENDING FROM BOLT HOLE OT FASTENER, 12 INCHES FROM TOP OF BS 560 FRAME. DYE CHECKED AREA TO CONFIRM CRACK TERMINATED IN BOLT AND FASTENER HOLES. FOUND NO FURTHER CRACK PROGRESSION. INSTALLED DOUBLER PER SRM 51-4-2 PAGE 1 FIG 1. (M)