What was found
TUL - FOUND STATION 970 STRINGER 27 RIGHT DOOR CUT OUT CORRODED CHORD ANGLE, SILL PLATE LOWER. BLENDED CORROSION, HFEC FASTENER HOLES. LIGHTLY SPOTFACED FASTENERS HOLES, AND FLAP PEENDED REWORK AREA PER ESO11697, DATED 3/29/99. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STATION 970 STRINGER 27 RIGHT DOOR CUT OUT CORRODED CHORD ANGLE, SILL PLATE LOWER. BLENDED CORROSION, HFEC FASTENER HOLES. LIGHTLY SPOTFACED FASTENERS HOLES, AND FLAP PEENDED REWORK AREA PER ESO11697, DATED 3/29/99. (M)