What was found
TUL - STATION 950A STIRNGER 19R, BELT FRAME HAS DEEP WEAR FROM CEILING PANEL, DAMAGE ON FREE FLANGE. INSTALLED DOUBLER PER 51-40-3. NO CUT OUT REQUIRED. DOUBLER PUT ON TOP OF FREE FLANGE AND WEB WAS .063 7075 MATERIAL 5.5 INCH LONG. 1 ROW OF 6 HI-LOCKS BACB30FN6-4 IN FREE FLANGE. WEB HAD 2 ROWS OF HI-LOCKS 1ST OVERSIZED. 1ST ROW WAS .1875 INCH BACB30FP6-4, 2ND ROW WAS .1875 INCH BACB30FP6-3. (M)