As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FOUND STATION 1030 BELL FRAME BENT (FLANGE/WEB) STRINGER 26-25 LEFT. REMOVED DAMGED SECTIONS, 1 INCH BY 2.8125 INCH BY 1 INCH BY 1.3125 INCH FROM BELL FRAME FLANGE, DYE CHECKED FOR CRACKS, NONE FOUND. INSTALLED DOUBLER PER SRM 51-40-3. (M)