As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - CUT OUT DAMAGE AT FS 720A PLUS 10 INCHES SPLICED IN NEW STRINGER. MATERIAL PER SRM 53-10-3 FIG 5. FASTENERS THROUGH SKIN FOUR .1875 HI-LOCKS PER SIDE OF SPLICE ALSO THROUGH LIP OF STRINGER. FOUR .15625 HI-LOCKS THROUGH SIDE OF 'J' CHANNEL PER SIDE, EACH SIDE OF SPLICE. (M)