What was found
MIA - DURING OVERNIGHT MAINTENANCE FORWARD GALLEY DOOR EMERGENCY EXIT LIGHTS AND FLOOR PATH LIGHTING INOPERATIVE. REPAIRED WIRE ON EMERGENCY EXIT FLOOR PATH LIGHT STRIP AND REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)