What was found
ORD - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHT AT ROWS 3D THROUGH 6D INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT CONDUCTOR AT ROWS 3D THROUGH 6D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ORD - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHT AT ROWS 3D THROUGH 6D INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT CONDUCTOR AT ROWS 3D THROUGH 6D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)