What was found
TUL - FOUND CORROSION ON AFT CX DOOR JAMB LOWER SILL BEAM FROM FRAME 59 TO FRAME 63. REMOVED CORROSION INSTALLED SILL BEAM REPAIR AT FRAME 60 IAW SRM 53-17-18 AND ESO 30595 DATED 11-17-99 AND DATED 11-22-99, OTHER BLENDOUTS THAT WERE OUT OF LIMITS PER SRM ARE OK PER ESO 30595 DATED 11-22-99 AFTER TREATING, PRIMING, PAINTING, AND APPLY A CORR PRSV COMPOUND. (M)