What was found
TUL - NUMEROUS SPOTS OF CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 75 AND 80 ON FLOOR TRACK E, RIGHT. INSTALLED NEW FLOOR TRACK E RIGHT, PER SRM 51-72-10-0. TST: 32,241.11 HOURS. CYCLES: 12,979. P/N A53278453200. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - NUMEROUS SPOTS OF CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 75 AND 80 ON FLOOR TRACK E, RIGHT. INSTALLED NEW FLOOR TRACK E RIGHT, PER SRM 51-72-10-0. TST: 32,241.11 HOURS. CYCLES: 12,979. P/N A53278453200. (X)