What was found
TUL - FOUND STRINGER 27L CORRODED INSIDE STATION 720E PLUS 5 INCH THROUGH 720E PLUS 7 INCH. REMOVED DAMAGED STRINGER 27L FROM STATION 720E PLUS 10 INCHES AND STATION 720F PLUS 10 INCH AND INSTALLED SPLICES AND FILLER PER SRM 53-10-3 PAGE 3. (M)