What was found
AFW - FOUND SMALL CRACK IN VERTICAL LEG OF FLOORBEAM AT STATION 783 RBL 11.06 AND LBL 11.06. REMOVED DAMAGED SECTION OF FLOORBEAM. SPLICED IN NEW SECTION OF FLOORBEAM. INSTALLED ALL REPAIR PARTS WET WITH BMS 5-95. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND SMALL CRACK IN VERTICAL LEG OF FLOORBEAM AT STATION 783 RBL 11.06 AND LBL 11.06. REMOVED DAMAGED SECTION OF FLOORBEAM. SPLICED IN NEW SECTION OF FLOORBEAM. INSTALLED ALL REPAIR PARTS WET WITH BMS 5-95. (M)