As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STATION 764 HAS CORROSION REMOVAL ON UPPER SURFACE MATERIAL REMAINING IS BEYOND SRM LIMITS. BLENDED AREA. FABRICATED REPAIR STRAP OUT OF 301.5 HARD STAINLESS STEEL .050 INCH THICK. ALODINED ALL BARE ALUMINUM SURFACES AND FINISHED BLENDS WITH BMS-5-92. INSTALLED REPAIR STRAP WET WITH BMS 5-95 SEALANT. (M)